| Setting temperature range |   20 to  80 °C |  
  | Working temperature range |  at least 5 above ambient temperature to  80 °C |  
  | Setting accuracy temperature |  0.1 °C |  
  | Temperature sensor |  2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error |  
  | ControlCOCKPIT |  TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. |  
  | Language setting |  German, English, Spanish, French, Polish, Czech, Hungarian |  
  | Timer |  Digital backwards counter with target time setting, adjustable from 1 minute to 99 days |  
  | Function HeatBALANCE |  adapting the distribution of the heating performance of the upper and lower heating circuit from -50 % to  50 % |  
  | Function SetpointWAIT |  the process time does not start until the set temperature is reached |  
  | Calibration |  three freely selectable temperature values |  
  | adjustable parameters |  temperature (Celsius or Fahrenheit), programme time, time zones, summertime/wintertime |  
  | Convection |  natural convection |  
  | Documentation |  programme stored in case of power failure |  
  | Programming |  AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port |  
  | Temperature control |  mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20°C above nominal temperature |  
  | Temperature control |  overtemperature monitor TWW, protection class 3.1 or adjustable temperature limiter TWB, protection class 2, selectable on display |  
  | AutoSAFETY |  additionally integrated over- and undertemperature monitor “ASF”, automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature |  
  | Autodiagnostic system |  for fault analysis |  
  | Alarm |  visual and acoustic |  
  | Works calibration certificate |  for  80°C |  
  | Door |  fully insulated stainless steel door with 2-point locking (compression door lock) |  
  | Internals |  2 stainless steel grid(s), electropolished |  
  | Interior |  nearly gas-tight interior |  
  | Interior |  easy-to-clean interior, made of stainless steel, reinforced by deep drawn ribbing with integrated and protected large-area heating on four sides |  
  | Volume |  161 l |  
  | Dimensions (interior) |  w(A) x h(B) x d(C): 560 x 720 x 400 mm |  
  | Max. number of internals |  8 |  
  | Max. loading of chamber |  210 kg |  
  | Max. loading per internal |  20 kg |  
  | Dimensions (exterior) |  w(D) x h(E) x d(F): 745 x 1104 x 584 mm (d  56mm door handle) |  
  | Housing |  rear zinc-plated steel |  
  | Voltage Electrical load |  230 V, 50/60 Hz approx. 3200 W |  
  | Voltage Electrical load |  115 V, 50/60 Hz approx. 1800 W |  
  | Altitude of installation |  max. 2,000 m above sea level |  
  | Ambient temperature |   5 °C to  40 °C |  
  | Humidity rh |  max. 80 %, non-condensing |  
  | Overvoltage category |  II |  
  | Pollution degree |  2 |